7P2G
Identification of low micromolar SARS-CoV-2 Mpro inhibitors from hits identified by in silico screens
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-04-16 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1.000 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 114.610, 53.790, 45.440 |
Unit cell angles | 90.00, 100.98, 90.00 |
Refinement procedure
Resolution | 48.530 - 2.500 |
R-factor | 0.2271 |
Rwork | 0.224 |
R-free | 0.27740 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6wqf |
RMSD bond length | 0.002 |
RMSD bond angle | 0.424 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (1.19.1_4122) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.530 | 2.590 |
High resolution limit [Å] | 2.500 | 2.500 |
Number of reflections | 31270 | 912 |
<I/σ(I)> | 8.38 | |
Completeness [%] | 98.7 | 97.33 |
Redundancy | 3.4 | 3.2 |
CC(1/2) | 0.983 | 0.208 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 293 | 0.1 M Tris, 25% (v/v) PEG 3350, 0.2 M lithium chloride |