7OWJ
Odinarchaeota Adenylate kinase (OdinAK) in complex with GTP
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | MAX IV BEAMLINE BioMAX |
Synchrotron site | MAX IV |
Beamline | BioMAX |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-03-29 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.9762 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 77.608, 78.787, 217.191 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 49.270 - 2.500 |
R-factor | 0.1904 |
Rwork | 0.187 |
R-free | 0.25800 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 7owe |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.270 | 2.590 |
High resolution limit [Å] | 2.500 | 2.500 |
Rmerge | 0.142 | 0.880 |
Rpim | 0.088 | 0.548 |
Number of reflections | 46830 | 4562 |
<I/σ(I)> | 8.2 | 2 |
Completeness [%] | 99.7 | 98.5 |
Redundancy | 6.8 | |
CC(1/2) | 0.994 | 0.708 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 291 | Protein in: 0.030 M MOPS, 0.050M NaCl, pH 6.8. Drop: 1:1 of Bis-Tris Propane pH 6.5 - 0.1 M, PEG 3350 12% Odin 0.853 mM, GTP 8.53 mM |