Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04 |
Synchrotron site | Diamond |
Beamline | I04 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-02-24 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9762 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 105.857, 105.857, 112.709 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 52.984 - 1.550 |
Rwork | 0.155 |
R-free | 0.17830 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 7oap |
RMSD bond length | 0.008 |
RMSD bond angle | 1.398 |
Data reduction software | xia2 |
Data scaling software | xia2 |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 53.000 | 1.590 |
High resolution limit [Å] | 1.550 | 1.550 |
Rpim | 0.020 | 0.590 |
Number of reflections | 93033 | 6677 |
<I/σ(I)> | 16.9 | 0.6 |
Completeness [%] | 100.0 | 93 |
Redundancy | 26.8 | 27.6 |
CC(1/2) | 1.000 | 0.600 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 1.0 M Lithium chloride, 0.1 M Citrate pH 4, 20 % Peg 6000 |