7NML
Galectin-1 in complex with 4-Amino-6-chloro-1,3-benzenedisulfonamide
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.1 |
Synchrotron site | BESSY |
Beamline | 14.1 |
Temperature [K] | 80 |
Detector technology | PIXEL |
Collection date | 2018-02-22 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9184 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 43.319, 58.475, 112.040 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 40.400 - 1.430 |
R-factor | 0.1775 |
Rwork | 0.176 |
R-free | 0.21110 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4q26 |
RMSD bond length | 0.011 |
RMSD bond angle | 1.100 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.18.2_3874) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.400 | 1.481 |
High resolution limit [Å] | 1.430 | 1.430 |
Number of reflections | 52116 | 32857 |
<I/σ(I)> | 13.17 | |
Completeness [%] | 97.0 | |
Redundancy | 6.56 | |
CC(1/2) | 0.990 | 0.466 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 287 | PEG 4000 |