7N2Q
AS4.3-YEIH-HLA*B27
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL12-1 |
Synchrotron site | SSRL |
Beamline | BL12-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-12-19 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.97946 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 54.977, 97.412, 175.484 |
Unit cell angles | 90.00, 92.33, 90.00 |
Refinement procedure
Resolution | 47.420 - 2.700 |
R-factor | 0.2155 |
Rwork | 0.213 |
R-free | 0.26400 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5KSB 1JGE |
RMSD bond length | 0.002 |
RMSD bond angle | 0.524 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.19.1_4122+SVN) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.710 | 2.790 |
High resolution limit [Å] | 2.700 | 2.700 |
Number of reflections | 49539 | 4552 |
<I/σ(I)> | 2.7 | |
Completeness [%] | 97.4 | |
Redundancy | 3.4 | |
CC(1/2) | 0.938 | 0.346 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 25% PEG3350 with 0.2M Ammonium sulfate and 0.1M BIS-TRIS pH 6.5 |