7N2P
AS4.3-RNASEH2b-HLA*B27
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 2.0.1 |
| Synchrotron site | ALS |
| Beamline | 2.0.1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-09-01 |
| Detector | DECTRIS PILATUS3 6M |
| Wavelength(s) | 1.046 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 54.925, 93.992, 177.774 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 47.000 | 2.589 |
| High resolution limit [Å] | 2.500 | 2.500 |
| Rmeas | 0.278 | 2.427 |
| Rpim | 0.130 | 1.123 |
| Number of reflections | 32459 | 3146 |
| <I/σ(I)> | 5.88 | 0.79 |
| Completeness [%] | 99.1 | 97.94 |
| Redundancy | 4.4 | 4.4 |
| CC(1/2) | 0.985 | 0.318 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | 20% PEG3350 with 0.2M Magnesium formate dihydrate |