Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7MQM

AAC(3)-IIIa in complex with CoA and gentamicin

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeLIQUID ANODE
Source detailsBRUKER METALJET
Temperature [K]100
Detector technologyPIXEL
Collection date2020-01-27
DetectorBruker PHOTON II
Wavelength(s)1.3418
Spacegroup nameP 21 21 2
Unit cell lengths130.574, 91.059, 100.524
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution31.048 - 1.600
R-factor0.1976
Rwork0.197
R-free0.21610
Structure solution methodFOURIER SYNTHESIS
RMSD bond length0.004
RMSD bond angle0.741
Data reduction softwarePROTEUM PLUS (2018.7-2)
Data scaling softwarePROTEUM PLUS (2018.7-2)
Phasing softwarePHASER (2.8.3)
Refinement softwarePHENIX ((1.15.1_3469: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]31.0501.657
High resolution limit [Å]1.6001.600
Number of reflections15794915589
<I/σ(I)>42.266.04
Completeness [%]99.499.7
Redundancy24
CC(1/2)0.9970.207
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP295.150.1M MES pH 6.5, 30% w/v PEG 4000, 3% v/v 1,3-propanediol

224931

PDB entries from 2024-09-11

PDB statisticsPDBj update infoContact PDBjnumon