7MJT
KcsA open gate E71V mutant with Barium
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 98 |
Detector technology | PIXEL |
Collection date | 2021-03-28 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.9792 |
Spacegroup name | I 4 |
Unit cell lengths | 140.489, 140.489, 69.680 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 20.000 - 3.300 |
R-factor | 0.2118 |
Rwork | 0.209 |
R-free | 0.26960 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5vk6 |
RMSD bond length | 0.009 |
RMSD bond angle | 1.675 |
Data reduction software | iMOSFLM |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 99.340 | 3.560 |
High resolution limit [Å] | 3.300 | 3.300 |
Number of reflections | 10372 | 2117 |
<I/σ(I)> | 11.3 | |
Completeness [%] | 99.9 | |
Redundancy | 6 | |
CC(1/2) | 0.995 | 0.649 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 50 mM sodium/ammonium acetate pH 5.5, 50 mM Magnesium acetate, 25% PG 400 |