7M2F
CDK2 with compound 14 inhibitor with carboxylate
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 17-ID |
Synchrotron site | APS |
Beamline | 17-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2014-01-30 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1.00 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 53.260, 71.100, 71.660 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 42.750 - 1.632 |
R-factor | 0.2131 |
Rwork | 0.211 |
R-free | 0.25750 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1b38 |
RMSD bond length | 0.008 |
RMSD bond angle | 0.960 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Refinement software | BUSTER (2.11.7 (29-NOV-2019)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 42.750 | 1.660 |
High resolution limit [Å] | 1.632 | 1.632 |
Rmerge | 0.053 | 0.824 |
Rpim | 0.023 | 0.351 |
Number of reflections | 31728 | 1690 |
<I/σ(I)> | 15.8 | |
Completeness [%] | 91.9 | |
Redundancy | 6.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 7.5 | 290 | 20% PEG 10K, 0.1M HEPES |