7LTA
Galectin-1 in complex with Trehalose
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.1 |
Synchrotron site | BESSY |
Beamline | 14.1 |
Temperature [K] | 80 |
Detector technology | PIXEL |
Collection date | 2018-04-23 |
Detector | DECTRIS PILATUS 2M |
Wavelength(s) | 0.918 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 42.788, 58.090, 112.467 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 40.400 - 1.530 |
R-factor | 0.2152 |
Rwork | 0.213 |
R-free | 0.24750 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4q26 |
RMSD bond length | 0.010 |
RMSD bond angle | 1.132 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHENIX (1.18.2_3874) |
Refinement software | PHENIX (1.18.2_3874) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.400 | 1.620 |
High resolution limit [Å] | 1.530 | 1.530 |
Number of reflections | 43161 | 6807 |
<I/σ(I)> | 10.37 | |
Completeness [%] | 99.9 | |
Redundancy | 6.52 | |
CC(1/2) | 0.990 | 0.530 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 289 | PEG 4000 |