7LTA

Galectin-1 in complex with Trehalose

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]80
Detector technologyPIXEL
Collection date2018-04-23
DetectorDECTRIS PILATUS 2M
Wavelength(s)0.918
Spacegroup nameP 21 21 21
Unit cell lengths42.788, 58.090, 112.467
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution40.400 - 1.530
R-factor0.2152
Rwork0.213
R-free0.24750
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4q26
RMSD bond length0.010
RMSD bond angle1.132
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHENIX (1.18.2_3874)
Refinement softwarePHENIX (1.18.2_3874)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]40.4001.620
High resolution limit [Å]1.5301.530
Number of reflections431616807
<I/σ(I)>10.37
Completeness [%]99.9
Redundancy6.52
CC(1/2)0.9900.530
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP289PEG 4000

225946