Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7LJZ

X-ray radiation damage series on Thaumatin at 277K, multi-conformer model, dataset 2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL9-2
Synchrotron siteSSRL
BeamlineBL9-2
Temperature [K]277
Detector technologyPIXEL
Collection date2018-11-28
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.88557
Spacegroup nameP 41 21 2
Unit cell lengths58.838, 58.838, 151.210
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution37.800 - 1.290
R-factor0.1451
Rwork0.144
R-free0.16000
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)7lfg
RMSD bond length0.009
RMSD bond angle1.079
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.18.2_3874)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]38.2801.310
High resolution limit [Å]1.2901.290
Rmerge0.1185.270
Rpim0.0421.868
Number of reflections678253363
<I/σ(I)>8.90.5
Completeness [%]99.998.1
Redundancy8.78.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.629324% Na K Tartrate (w/v), 15% ethylene glycol (v/v), and 0.1 M BisTris Propane

227344

PDB entries from 2024-11-13