7LGA
PEG10 CA-like C-terminal domain
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 22-BM |
| Synchrotron site | APS |
| Beamline | 22-BM |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2019-06-04 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.9791 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 51.598, 70.289, 52.689 |
| Unit cell angles | 90.00, 98.10, 90.00 |
Refinement procedure
| Resolution | 41.890 - 1.900 |
| R-factor | 0.1842 |
| Rwork | 0.182 |
| R-free | 0.20930 |
| Structure solution method | SAD |
| RMSD bond length | 0.006 |
| RMSD bond angle | 0.763 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHENIX (1.18_3845) |
| Refinement software | PHENIX (1.18_3845) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.930 |
| High resolution limit [Å] | 1.900 | 1.900 |
| Number of reflections | 58024 | 1166 |
| <I/σ(I)> | 19.625 | |
| Completeness [%] | 98.4 | |
| Redundancy | 7.2 | |
| CC(1/2) | 0.992 | 0.644 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.1 M HEPES, pH 7.5 25% (w/v) PEG 3,350 0.2 M NaCl |