Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7KXO

BTK1 SOAKED WITH COMPOUND 24

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X1A
Synchrotron siteNSLS
BeamlineX1A
Temperature [K]100
Detector technologyPIXEL
Collection date2017-03-22
DetectorDECTRIS PILATUS 2M
Wavelength(s)1.00003
Spacegroup nameP 21 21 2
Unit cell lengths72.760, 103.550, 38.540
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution38.540 - 1.940
R-factor0.2046
Rwork0.202
R-free0.24840
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1k2p
RMSD bond length0.012
RMSD bond angle1.590
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwareREFMAC
Refinement softwareREFMAC (5.8.0158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.260
High resolution limit [Å]1.1901.190
Rmerge0.1511.800
Number of reflections9329293292
<I/σ(I)>7.870.4
Completeness [%]98.999.1
Redundancy6.165.87
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.529820% PEG 3350 0.1 M Bis Tris Propane pH 7.5 0.2 M Sodium acetate trihydrate

223790

PDB entries from 2024-08-14

PDB statisticsPDBj update infoContact PDBjnumon