7KTC
DNA Polymerase Mu, 8-oxodGTP:Ct Product State Ternary Complex, 10 mM Mn2+ (120min)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2016-07-22 |
Detector | RAYONIX MX300-HS |
Wavelength(s) | 1.00 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 60.272, 62.354, 118.901 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 35.020 - 1.653 |
R-factor | 0.1567 |
Rwork | 0.156 |
R-free | 0.17610 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4m04 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.15.2_3472) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 50.000 | 1.680 |
High resolution limit [Å] | 1.650 | 4.480 | 1.650 |
Rmerge | 0.098 | 0.082 | 0.709 |
Rmeas | 0.108 | 0.091 | 0.806 |
Rpim | 0.043 | 0.037 | 0.378 |
Total number of observations | 319975 | ||
Number of reflections | 54399 | 2933 | 2660 |
<I/σ(I)> | 8.8 | ||
Completeness [%] | 99.9 | 99.1 | 99.8 |
Redundancy | 5.9 | 5.8 | 4.4 |
CC(1/2) | 0.982 | 0.715 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 277 | 85-90mM HEPES pH 7.5, 17-18% PEG4000 |