Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7K0Z

Marsupial T cell receptor Spl_157

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX1
Synchrotron siteAustralian Synchrotron
BeamlineMX1
Temperature [K]100
Detector technologyPIXEL
Collection date2020-06-10
DetectorDECTRIS EIGER2 X 9M
Wavelength(s)0.9537
Spacegroup nameP 21 21 21
Unit cell lengths72.328, 110.722, 207.798
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution47.030 - 3.200
R-factor0.2585
Rwork0.257
R-free0.28550
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)unpublished
RMSD bond length0.003
RMSD bond angle0.806
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.17.1_3660)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.0303.390
High resolution limit [Å]3.2003.200
Rpim0.0600.545
Number of reflections283674496
<I/σ(I)>10.61.6
Completeness [%]100.0
Redundancy13.4
CC(1/2)0.998
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2930.1M CBTP pH 8.8, 15-20% PEG 3350

222926

PDB entries from 2024-07-24

PDB statisticsPDBj update infoContact PDBjnumon