7JXM
EGFR kinase (T790M/V948R) in complex with osimertinib and EAI045
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-10-18 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.9792 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 72.548, 103.224, 87.043 |
Unit cell angles | 90.00, 101.55, 90.00 |
Refinement procedure
Resolution | 49.909 - 2.192 |
R-factor | 0.228 |
Rwork | 0.227 |
R-free | 0.27050 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5d41 |
RMSD bond length | 0.009 |
RMSD bond angle | 1.071 |
Data reduction software | xia2 |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (1.11.1_2575) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 49.909 | 49.909 | 2.320 |
High resolution limit [Å] | 2.190 | 6.520 | 2.190 |
Rmerge | 0.208 | 0.052 | 0.812 |
Rmeas | 0.247 | 0.063 | 0.977 |
Number of reflections | 120584 | 2444 | 9574 |
<I/σ(I)> | 8.95 | 23.99 | 1.56 |
Completeness [%] | 97.4 | 96.7 | 92.4 |
Redundancy | 3.442 | 3.158 | 3.204 |
CC(1/2) | 0.973 | 0.995 | 0.702 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5.5 | 293 | 0.1 M Bis-Tris pH 5.5, 28% (w/v) PEG 3350 |