7JTN

Human Complement Factor B Inhibited by a Slow Off-Rate Modified Aptamer of 29 Bases

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2018-11-26
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.97243
Spacegroup nameP 1 21 1
Unit cell lengths87.126, 144.407, 87.185
Unit cell angles90.00, 109.46, 90.00
Refinement procedure
Resolution42.900 - 3.100
R-factor0.2098
Rwork0.208
R-free0.24130
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2ok5
RMSD bond length0.013
RMSD bond angle1.621
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwarePHENIX (v1.17)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0003.210
High resolution limit [Å]3.1006.6703.100
Rmerge0.2260.1270.864
Rmeas0.2480.1390.985
Rpim0.1010.0540.461
Total number of observations209444
Number of reflections3650937243525
<I/σ(I)>4.7
Completeness [%]99.499.996
Redundancy5.76.44.1
CC(1/2)0.9560.573
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.52930.1 M bis-tris, 0.2 M ammonium acetate, 25% peg-3350

222624

PDB entries from 2024-07-17

PDB statisticsPDBj update infoContact PDBjnumon