7IIA
Endothiapepsin crystal B4a from ECBL follow-up screening campaign used for PanDDA ground state calculation
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | BESSY BEAMLINE 14.2 |
| Synchrotron site | BESSY |
| Beamline | 14.2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-09-28 |
| Detector | DECTRIS PILATUS3 2M |
| Wavelength(s) | 0.9184 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 45.460, 73.330, 52.810 |
| Unit cell angles | 90.00, 109.50, 90.00 |
Refinement procedure
| Resolution | 39.680 - 1.390 |
| R-factor | 0.1543 |
| Rwork | 0.153 |
| R-free | 0.19110 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 0.871 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.17_3644: ???)) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 39.680 | 4.140 | 1.470 |
| High resolution limit [Å] | 1.390 | 2.940 | 1.390 |
| Rmerge | 0.123 | 0.049 | 1.404 |
| Rmeas | 0.140 | 0.055 | 1.612 |
| Total number of observations | 295104 | ||
| Number of reflections | 65751 | 4530 | 10298 |
| <I/σ(I)> | 8.16 | 28.47 | 0.89 |
| Completeness [%] | 99.3 | ||
| CC(1/2) | 0.997 | 0.997 | 0.437 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 4.6 | 293 | 29 % (w/v) PEG 4000, 0.1 M ammonium acetate and 0.1 M sodium acetate, pH 4.6 |