7II9
Endothiapepsin crystal B9a from ECBL follow-up screening campaign used for PanDDA ground state calculation
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | BESSY BEAMLINE 14.2 |
| Synchrotron site | BESSY |
| Beamline | 14.2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-09-28 |
| Detector | DECTRIS PILATUS3 2M |
| Wavelength(s) | 0.9184 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 45.270, 73.160, 52.570 |
| Unit cell angles | 90.00, 109.39, 90.00 |
Refinement procedure
| Resolution | 28.080 - 1.100 |
| R-factor | 0.1558 |
| Rwork | 0.155 |
| R-free | 0.17210 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.005 |
| RMSD bond angle | 0.872 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.17_3644: ???)) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 28.080 | 3.280 | 1.160 |
| High resolution limit [Å] | 1.100 | 2.320 | 1.100 |
| Rmerge | 0.111 | 0.061 | 1.437 |
| Rmeas | 0.126 | 0.070 | 1.660 |
| Total number of observations | 566756 | ||
| Number of reflections | 130811 | 9011 | 19865 |
| <I/σ(I)> | 6.56 | 21.96 | 0.74 |
| Completeness [%] | 98.7 | ||
| CC(1/2) | 0.997 | 0.990 | 0.432 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 4.6 | 293 | 29 % (w/v) PEG 4000, 0.1 M ammonium acetate and 0.1 M sodium acetate, pH 4.6 |






