7IGD
Endothiapepsin crystal Apo18 from ECBL-96 fragment library screening campaign used for PanDDA ground state calculation
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | BESSY BEAMLINE 14.1 |
| Synchrotron site | BESSY |
| Beamline | 14.1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-06-12 |
| Detector | DECTRIS PILATUS3 6M |
| Wavelength(s) | 0.9184 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 45.320, 73.040, 52.540 |
| Unit cell angles | 90.00, 109.32, 90.00 |
Refinement procedure
| Resolution | 29.400 - 1.060 |
| R-factor | 0.1477 |
| Rwork | 0.147 |
| R-free | 0.16090 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.005 |
| RMSD bond angle | 0.882 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.17_3644: ???)) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 29.400 | 3.170 | 1.120 |
| High resolution limit [Å] | 1.060 | 2.240 | 1.060 |
| Rmerge | 0.075 | 0.037 | 1.496 |
| Rmeas | 0.089 | 0.044 | 1.782 |
| Total number of observations | 470842 | ||
| Number of reflections | 139022 | 9889 | 21084 |
| <I/σ(I)> | 7.97 | 28.83 | 0.68 |
| Completeness [%] | 94.9 | ||
| CC(1/2) | 0.998 | 0.998 | 0.375 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 4.6 | 293 | 29 % (w/v) PEG 4000, 0.1 M ammonium acetate and 0.1 M sodium acetate, pH 4.6 |