7ID8
PanDDA analysis group deposition -- SARS-CoV-2 Nsp1 crystal C11 (dataset 1) from the KIT library screening campaign, data used for ground state calculation
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.1 |
Synchrotron site | BESSY |
Beamline | 14.1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2023-05-02 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.9184 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 36.670, 36.670, 142.220 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 35.530 - 1.840 |
R-factor | 0.19969 |
Rwork | 0.197 |
R-free | 0.24741 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.008 |
RMSD bond angle | 1.500 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 35.530 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 293 | 0.1 M HEPES pH 7.5 and 25% (w/v) PEG 3350. Reproducibility was improved by seeding. |