Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

7FVQ

PanDDA analysis group deposition -- PHIP in complex with Z68576046

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2022-09-24
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.92124
Spacegroup nameC 1 2 1
Unit cell lengths81.891, 27.434, 56.337
Unit cell angles90.00, 99.96, 90.00
Refinement procedure
Resolution55.490 - 1.150
R-factor0.1663
Rwork0.165
R-free0.18920
Structure solution methodFOURIER SYNTHESIS
Starting model (for MR)7av9
RMSD bond length0.013
RMSD bond angle1.628
Data reduction softwareXDS
Data scaling softwareAimless (0.7.7)
Phasing softwareREFMAC
Refinement softwareREFMAC (5.8.0267)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]55.50055.5001.170
High resolution limit [Å]1.1506.3001.150
Rmerge0.0580.0870.240
Rmeas0.0630.0980.339
Rpim0.0250.0430.240
Total number of observations1747011758138
Number of reflections30306
<I/σ(I)>22.541.41
Completeness [%]68.699.45.9
Redundancy5.85.91.1
CC(1/2)0.9940.9640.656
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP5.627720% PEG 8000, 0.04M potassium phosphate

237735

PDB entries from 2025-06-18

PDB statisticsPDBj update infoContact PDBjnumon