Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7FVA

PanDDA analysis group deposition -- PHIP in complex with Z4913872963

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2022-09-24
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.92124
Spacegroup nameC 1 2 1
Unit cell lengths82.024, 27.381, 56.258
Unit cell angles90.00, 99.49, 90.00
Refinement procedure
Resolution30.410 - 1.190
R-factor0.2558
Rwork0.255
R-free0.26850
Structure solution methodFOURIER SYNTHESIS
Starting model (for MR)7av9
RMSD bond length0.016
RMSD bond angle1.674
Data reduction softwareXDS
Data scaling softwareAimless (0.7.7)
Phasing softwareREFMAC
Refinement softwareREFMAC (5.8.0403)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]30.40030.4001.210
High resolution limit [Å]1.1906.5201.190
Rmerge0.0450.0870.326
Rmeas0.0500.0970.452
Rpim0.0200.0430.312
Total number of observations1734991495615
Number of reflections33580
<I/σ(I)>26.852.11.4
Completeness [%]84.299.124.2
Redundancy5.25.41.3
CC(1/2)0.9940.9700.868
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP5.627720% PEG 8000, 0.04M potassium phosphate

223532