7EZY
anti-CRISPR-associated Aca2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PAL/PLS BEAMLINE 5C (4A) |
Synchrotron site | PAL/PLS |
Beamline | 5C (4A) |
Temperature [K] | 125 |
Detector technology | PIXEL |
Collection date | 2021-03-24 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 1.000 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 64.130, 64.130, 135.520 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 28.980 - 1.920 |
R-factor | 0.2007 |
Rwork | 0.198 |
R-free | 0.23190 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4a4a |
RMSD bond length | 0.009 |
RMSD bond angle | 1.172 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHENIX |
Refinement software | PHENIX (1.19.1_4122) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 28.980 | 1.989 |
High resolution limit [Å] | 1.920 | 1.920 |
Rmeas | 0.138 | |
Number of reflections | 22344 | 2162 |
<I/σ(I)> | 19.56 | |
Completeness [%] | 99.8 | |
Redundancy | 25.8 | |
CC(1/2) | 0.669 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293.15 | 25% PEG 1000, 0.1M Tris base pH 8.9 |