7EY1
Bifunctional xylosidase/glucosidase LXYL with intermediate substrate xylose
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-10-21 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.979 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 228.508, 88.174, 218.500 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 218.500 - 2.460 |
Rwork | 0.196 |
R-free | 0.24900 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6kj0 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | REFMAC (5) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 218.500 | 2.500 |
High resolution limit [Å] | 2.460 | 2.460 |
Rmerge | 0.144 | 0.537 |
Number of reflections | 158265 | 7844 |
<I/σ(I)> | 10.3 | |
Completeness [%] | 98.7 | |
Redundancy | 5.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 289.15 | 15% PEG 3350, 0.1M Hepes pH 7.5, 0.2% MgCl2 |