Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7EHR

Levansucrase from Brenneria sp. EniD 312 at 1.33 angstroms resolution

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL18U1
Synchrotron siteSSRF
BeamlineBL18U1
Temperature [K]100
Detector technologyPIXEL
Collection date2017-12-10
DetectorDECTRIS PILATUS3 6M
Wavelength(s)0.97853
Spacegroup nameP 61 2 2
Unit cell lengths98.000, 98.000, 213.539
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution84.800 - 1.330
Rwork0.164
R-free0.17600
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4d47
RMSD bond length0.014
RMSD bond angle1.685
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0258)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]84.8701.400
High resolution limit [Å]1.3301.330
Rpim0.0190.012
Number of reflections1380386204
<I/σ(I)>20.1
Completeness [%]90.334.5
Redundancy36.816.1
CC(1/2)0.9990.706
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5298.15Ammonium sulfate, PEG 400

224201

PDB entries from 2024-08-28

PDB statisticsPDBj update infoContact PDBjnumon