7C8X
Blasnase-T13A with L-asn
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL18U1 |
Synchrotron site | SSRF |
Beamline | BL18U1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-10-01 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 0.9791 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 92.256, 92.256, 232.931 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 49.292 - 1.994 |
Rwork | 0.175 |
R-free | 0.19110 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1o7j |
RMSD bond length | 0.015 |
RMSD bond angle | 1.691 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0258) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.292 | 2.040 |
High resolution limit [Å] | 1.990 | 1.990 |
Rpim | 0.027 | 0.323 |
Number of reflections | 69445 | 4255 |
<I/σ(I)> | 16 | 1.7 |
Completeness [%] | 99.7 | |
Redundancy | 23.4 | |
CC(1/2) | 0.999 | 0.703 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 295 | Formate |