Notum_Valsartan complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2017-02-27
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.9282
Spacegroup nameP 21 21 21
Unit cell lengths60.344, 73.990, 78.833
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution53.950 - 1.370
R-factor0.1854
Rwork0.184
R-free0.21770
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4uz1
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwareMOLREP
Refinement softwarePHENIX (1.18.2_3874)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]73.9901.390
High resolution limit [Å]1.3701.370
Number of reflections748453654
<I/σ(I)>12.5
Completeness [%]100.0
Redundancy12.8
CC(1/2)1.0000.483
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2961.5 M Ammonium Sulphate 0.1 M Sodium Citrate, pH4.2

222415

PDB entries from 2024-07-10