7BDQ
MAPK14 bound with SR300
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-02-01 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1.000 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 65.027, 73.041, 74.347 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.900 - 2.750 |
R-factor | 0.2178 |
Rwork | 0.215 |
R-free | 0.26160 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5lar |
RMSD bond length | 0.006 |
RMSD bond angle | 1.399 |
Data reduction software | Aimless (0.7.4) |
Data scaling software | Aimless (0.7.4) |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 48.950 | 48.950 | 2.900 |
High resolution limit [Å] | 2.750 | 8.700 | 2.750 |
Rmerge | 0.217 | 0.091 | 1.544 |
Rmeas | 0.244 | 0.103 | 1.735 |
Rpim | 0.110 | 0.047 | 0.774 |
Total number of observations | 1414 | 6284 | |
Number of reflections | 9622 | 361 | 1376 |
<I/σ(I)> | 5.9 | 8.8 | 2.7 |
Completeness [%] | 99.6 | 99.6 | 99.7 |
Redundancy | 4.4 | 3.9 | 4.6 |
CC(1/2) | 0.977 | 0.987 | 0.446 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6 | 277 | 14% HMW PgSmear, 0.1M MES |