7B7W

Notum-Fragment049

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2017-02-02
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.9282
Spacegroup nameP 21 21 21
Unit cell lengths60.003, 72.680, 78.475
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution53.320 - 1.600
R-factor0.2061
Rwork0.205
R-free0.22670
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4uzq
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwareMOLREP
Refinement softwarePHENIX (1.18.2_3874)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]72.6801.630
High resolution limit [Å]1.6001.600
Number of reflections460112176
<I/σ(I)>10.2
Completeness [%]99.9
Redundancy6.3
CC(1/2)1.0000.557
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1EVAPORATION4.22961.5 M Ammonium Sulphate 0.1 M Sodium Citrate

222926

PDB entries from 2024-07-24

PDB statisticsPDBj update infoContact PDBjnumon