Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7B7R

MEK1 in complex with compound 4

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]100
Detector technologyPIXEL
Collection date2017-05-22
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.98
Spacegroup nameP 21 21 21
Unit cell lengths57.640, 71.650, 157.810
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution24.690 - 1.700
R-factor0.195
Rwork0.194
R-free0.21800
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3e8n
RMSD bond length0.010
RMSD bond angle1.090
Data reduction softwareXDS
Data scaling softwareAimless (0.5.32)
Phasing softwarePHASER
Refinement softwareBUSTER (2.11.7)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]54.0001.740
High resolution limit [Å]1.7001.700
Rmerge0.0400.673
Number of reflections727983764
<I/σ(I)>21.72.1
Completeness [%]99.9
Redundancy6.4
CC(1/2)0.9900.770
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP293Crystals were obtained from hanging drops by mixing a 1:1 ratio of protein solution with well solution containing 2 M AmSO4, 0.1 M NaCl and 0.1 M Bis-tris pH 6.1-6.2