Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7B37

Notum complex with ARUK3003718

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I03
Synchrotron siteDiamond
BeamlineI03
Temperature [K]100
Detector technologyPIXEL
Collection date2020-11-24
DetectorDECTRIS EIGER2 XE 16M
Wavelength(s)0.9763
Spacegroup nameP 21 21 21
Unit cell lengths60.163, 71.546, 78.124
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.050 - 1.340
R-factor0.1931
Rwork0.193
R-free0.20260
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)7arg
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwareMOLREP
Refinement softwarePHENIX (1.18.2_3874)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]78.1201.360
High resolution limit [Å]1.3401.340
Number of reflections764523720
<I/σ(I)>21.1
Completeness [%]100.0
Redundancy50.5
CC(1/2)1.0000.848
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1EVAPORATION4.22961.5 M Ammonium Sulphate 0.1 M Sodium Citrate

227561

PDB entries from 2024-11-20

PDB statisticsPDBj update infoContact PDBjnumon