7B01
ADAMTS13-CUB12
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04 |
Synchrotron site | Diamond |
Beamline | I04 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-10-18 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.9159 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 105.576, 105.576, 125.837 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 70.000 - 2.800 |
R-factor | 0.2053 |
Rwork | 0.201 |
R-free | 0.29170 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6i58 |
RMSD bond length | 0.005 |
RMSD bond angle | 1.505 |
Data reduction software | Aimless |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0238) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 75.110 | 2.700 |
High resolution limit [Å] | 2.660 | 2.660 |
Number of reflections | 86169 | 7612 |
<I/σ(I)> | 12 | |
Completeness [%] | 92.2 | |
Redundancy | 6.8 | |
CC(1/2) | 0.990 | 0.084 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 21% (v/v) PEG1500, 100 mM Sodium propionate, sodium cacodylate trihydrate, 200 mM MnCl2, Bis-Tris propane, pH 5 |