7AEU
Pressure wave-exposed human hemoglobin: probe only data (5500 indexed images)
This is a non-PDB format compatible entry.
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | FREE ELECTRON LASER |
Source details | SLAC LCLS BEAMLINE CXI |
Synchrotron site | SLAC LCLS |
Beamline | CXI |
Temperature [K] | 293 |
Detector technology | PIXEL |
Collection date | 2018-01-01 |
Detector | CS-PAD CXI-2 |
Wavelength(s) | 1.74 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 55.700, 158.100, 67.700 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 28.060 - 2.540 |
Rwork | 0.207 |
R-free | 0.27270 |
Structure solution method | FOURIER SYNTHESIS |
RMSD bond length | 0.007 |
RMSD bond angle | 1.549 |
Data reduction software | CrystFEL |
Data scaling software | CrystFEL |
Phasing software | REFMAC |
Refinement software | REFMAC (5.8.0258) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 28.480 | 2.610 |
High resolution limit [Å] | 2.540 | 2.540 |
Number of reflections | 20352 | 989 |
<I/σ(I)> | 2.4 | |
Completeness [%] | 100.0 | |
Redundancy | 28.6 | |
CC(1/2) | 0.798 | 0.317 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | BATCH MODE | 293 | 3.2 M NaH2PO4/ 3.2 M K2HPO4 in a 2:1 ratio |