7AAF
Structural evolution of the tissue-specific U2AF2 paralog and alternative splicing factor LS2
Spectrometer
Experimental method: SOLUTION NMR
Spectrometer ID | Spectrometer maker | Spectrometer model | Spectrometer type | Spectrometer field strength |
1 | Bruker | AVANCE 750 | 750 | |
2 | Bruker | AVANCE 800 | 800 | |
3 | Bruker | AVANCE 900 | 900 |
Experiment
experiment id | conditions id | solution id | Experiment type |
1 | 1 | 1 | 2D 1H-15N HSQC |
2 | 1 | 1 | 2D 1H-13C HSQC aliphatic |
3 | 1 | 1 | 2D 1H-13C HSQC aromatic |
4 | 1 | 1 | 3D HNCACB |
5 | 1 | 1 | 3D HNCA |
6 | 1 | 1 | 3D 1H-13C NOESY aliphatic |
8 | 1 | 1 | 3D 1H-15N NOESY |
9 | 1 | 1 | 3D 1H-13C NOESY aromatic |
NMR Sample
conditions id | NMR sample pH | NMR sample pressure | NMR sample temperature |
1 | 6.5 | 1 | 298 |
Conformers
Conformers Calculated Total Number | 40 |
Conformers Submitted Total Number | 10 |