rsGreen0.7-K206A-F165W partially in the green-off state

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 1
Synchrotron siteSOLEIL
BeamlinePROXIMA 1
Temperature [K]100
Detector technologyPIXEL
Collection date2015-07-09
DetectorDECTRIS PILATUS3 6M
Wavelength(s)0.97857
Spacegroup nameH 3 2
Unit cell lengths140.744, 140.744, 72.897
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution46.756 - 2.200
R-factor0.2078
Rwork0.205
R-free0.26130
RMSD bond length0.002
RMSD bond angle0.542
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHENIX (1.11)
Refinement softwarePHENIX (1.11)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]46.76046.7602.270
High resolution limit [Å]2.2009.0702.200
Rmerge0.0580.0300.657
Rmeas0.0600.0310.675
Rpim0.0130.0070.154
Total number of observations284967387123391
Number of reflections141482251211
<I/σ(I)>32.186.15.3
Completeness [%]100.099.499.9
Redundancy20.117.219.3
CC(1/2)1.0000.9990.964
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293100 mM HEPES pH 7.5 25 % PEG 4000

220113

PDB entries from 2024-05-22