rsGreen0.7-K206A-F145H partially in the green-off state

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 2
Synchrotron siteSOLEIL
BeamlinePROXIMA 2
Temperature [K]100
Detector technologyPIXEL
Collection date2017-06-28
DetectorDECTRIS EIGER X 9M
Wavelength(s)0.9801
Spacegroup nameH 3 2
Unit cell lengths139.973, 139.973, 73.236
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution46.693 - 2.100
R-factor0.2233
Rwork0.221
R-free0.26880
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle0.971
Data reduction softwareXDS
Data scaling softwareAimless (0.5.32)
Phasing softwarePHASER (2.7.16)
Refinement softwarePHENIX (1.11)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]46.69046.6902.160
High resolution limit [Å]2.1008.9102.100
Rmerge0.0460.0280.768
Rmeas0.0470.0290.786
Rpim0.0100.0070.168
Total number of observations323440383928112
Number of reflections159712361294
<I/σ(I)>36.8975
Completeness [%]99.198.698.3
Redundancy20.316.321.7
CC(1/2)1.0001.0000.976
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293100 mM MES pH 6.0 14 % PEG 400 300 mM NGSB-195

223166

PDB entries from 2024-07-31

PDB statisticsPDBj update infoContact PDBjnumon