7A7Z

rsGreen0.7-K206A-E222G in the green-on state

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsELETTRA BEAMLINE 5.2R
Synchrotron siteELETTRA
Beamline5.2R
Temperature [K]100
Detector technologyPIXEL
Collection date2017-07-19
DetectorDECTRIS PILATUS 2M
Wavelength(s)1
Spacegroup nameI 1 2 1
Unit cell lengths48.245, 61.556, 93.098
Unit cell angles90.00, 97.41, 90.00
Refinement procedure
Resolution40.402 - 1.100
R-factor0.1235
Rwork0.122
R-free0.14240
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle1.034
Data reduction softwareXDS
Data scaling softwareAimless (0.5.32)
Phasing softwarePHASER (2.7.16)
Refinement softwarePHENIX (1.11)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]44.91044.9101.120
High resolution limit [Å]1.1006.0201.100
Rmerge0.0290.0170.623
Rmeas0.0330.0190.740
Rpim0.0170.0090.392
Total number of observations273718148
Number of reflections1088907005350
<I/σ(I)>16.759.41.8
Completeness [%]99.699.199.7
Redundancy3.63.93.4
CC(1/2)1.0000.9990.879
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293200 mM (Li)2SO4 100 mM Tris pH 8.5 40 % PEG 400