Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7A7R

rsGreenF-K206A in the green-off state

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 2
Synchrotron siteSOLEIL
BeamlinePROXIMA 2
Temperature [K]100
Detector technologyPIXEL
Collection date2017-06-28
DetectorDECTRIS EIGER X 9M
Wavelength(s)0.9801
Spacegroup nameP 41 21 2
Unit cell lengths106.185, 106.185, 35.907
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution47.487 - 2.350
R-factor0.1774
Rwork0.174
R-free0.24320
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.001
RMSD bond angle0.459
Data reduction softwareXDS
Data scaling softwareAimless (0.5.32)
Phasing softwarePHENIX (1.11)
Refinement softwarePHENIX
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]47.49047.4902.430
High resolution limit [Å]2.3509.1002.350
Rmerge0.1460.0620.667
Rmeas0.1520.0670.695
Rpim0.0430.0220.196
Total number of observations184711045
Number of reflections9057199870
<I/σ(I)>16.328.24.7
Completeness [%]100.099.5100
Redundancy12.49.312.7
CC(1/2)0.9970.9950.915
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293200 mM NaCl 100 mM MES pH 6.0 20 % PEG 6000

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon