Pcc1Pcc2 complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 2
Synchrotron siteSOLEIL
BeamlinePROXIMA 2
Temperature [K]100
Detector technologyPIXEL
Collection date2018-09-14
DetectorDECTRIS EIGER2 X 9M
Wavelength(s)0.980066
Spacegroup nameP 32 2 1
Unit cell lengths69.898, 69.898, 92.751
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution34.950 - 3.180
R-factor0.192
Rwork0.185
R-free0.25000
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3enc
RMSD bond length0.010
RMSD bond angle1.250
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwareBUSTER (2.10.3)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]34.95034.9503.360
High resolution limit [Å]3.1709.2403.170
Rmerge0.2120.0701.796
Rmeas0.2180.0731.847
Total number of observations87363
Number of reflections4659219678
<I/σ(I)>10.9337.931.54
Completeness [%]98.498.291
Redundancy18.75117.30117.488
CC(1/2)0.9970.9980.859
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29815% PEG 6000 and 5% glycerol

222926