7ZSW
F32V Cytochrome c prime beta from Methylococcus capsulatus (Bath): NO Complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I04 |
| Synchrotron site | Diamond |
| Beamline | I04 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2020-12-01 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.90001 |
| Spacegroup name | P 21 3 |
| Unit cell lengths | 105.913, 105.913, 105.913 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 61.150 - 1.940 |
| R-factor | 0.1885 |
| Rwork | 0.187 |
| R-free | 0.20660 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 6hih |
| RMSD bond length | 0.013 |
| RMSD bond angle | 2.211 |
| Data reduction software | DIALS |
| Data scaling software | xia2 |
| Phasing software | REFMAC |
| Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 61.150 | 61.170 | 1.980 |
| High resolution limit [Å] | 1.940 | 5.280 | 1.950 |
| Rmeas | 0.123 | 0.044 | 2.939 |
| Rpim | 0.036 | 0.013 | 0.905 |
| Total number of observations | 17536 | 15069 | |
| Number of reflections | 29298 | 1570 | 1447 |
| <I/σ(I)> | 13.5 | 61.2 | 0.5 |
| Completeness [%] | 100.0 | 100 | 100 |
| Redundancy | 11.4 | 11.2 | 10.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 291 | 2 microlitres of 15 mg/ml protein in 0.1 M HEPES buffer, pH 7.5, mixed with with an equivalent volume of reservoir solution containing 0.01 M ZnSO4, 30% PEG 550 (v/v) and 0.1 M MES, pH 6.5. Cryoprotection in ML plus 10% glycerol |