GSTF sh101 mutant

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsEMBL/DESY, HAMBURG BEAMLINE X13
Synchrotron siteEMBL/DESY, HAMBURG
BeamlineX13
Temperature [K]100
Detector technologyPIXEL
Collection date2020-11-30
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9763
Spacegroup nameC 1 2 1
Unit cell lengths92.450, 46.382, 110.822
Unit cell angles90.00, 112.04, 90.00
Refinement procedure
Resolution42.850 - 1.870
R-factor0.2016
Rwork0.200
R-free0.23330
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6riv
RMSD bond length0.008
RMSD bond angle0.983
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]45.9701.930
High resolution limit [Å]1.8701.870
Rmeas0.0872.934
Number of reflections362973552
<I/σ(I)>50.7
Completeness [%]99.8
Redundancy6.7
CC(1/2)0.9900.280
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2890.2M sodium chloride, 0.1M MES, 30% v/v Jeffamine ED-2003, pH 6