7Z74
PI3KC2a core in complex with PITCOIN2
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | BESSY BEAMLINE 14.1 |
| Synchrotron site | BESSY |
| Beamline | 14.1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-04-07 |
| Detector | DECTRIS PILATUS3 6M |
| Wavelength(s) | 0.9184 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 56.309, 135.151, 151.916 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 43.260 - 2.500 |
| R-factor | 0.2281 |
| Rwork | 0.226 |
| R-free | 0.26990 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 7bi4 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.18.2_3874) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 43.260 | 2.589 |
| High resolution limit [Å] | 2.500 | 2.500 |
| Number of reflections | 41035 | 4007 |
| <I/σ(I)> | 9.02 | |
| Completeness [%] | 99.7 | 99.68 |
| Redundancy | 5.5 | |
| CC(1/2) | 0.998 | 0.172 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION | 7.5 | 298 | 0.1MTris, 8-6% PEG3350, 0.2-0.1M MgSO4 |