Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7Z5H

human Zn MATCAP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06DA
Synchrotron siteSLS
BeamlineX06DA
Temperature [K]100
Detector technologyPIXEL
Collection date2020-04-20
DetectorDECTRIS PILATUS 2M-F
Wavelength(s)1.280960
Spacegroup nameP 1 21 1
Unit cell lengths55.646, 88.067, 165.581
Unit cell angles90.00, 90.77, 90.00
Refinement procedure
Resolution47.083 - 2.500
Rwork0.232
R-free0.25500
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)7z5g
RMSD bond length0.006
RMSD bond angle0.978
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0267)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]47.08347.0402.570
High resolution limit [Å]2.50010.6102.500
Rmerge0.1730.0301.727
Rmeas0.2040.0362.038
Rpim0.1080.0191.073
Number of reflections555427734531
<I/σ(I)>9.1
Completeness [%]100.0
Redundancy6.86.57
CC(1/2)0.9960.9990.560
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2930.1M HEPES-NaOH, 4.3M NaCl, 2 uM ZnCl2, pH 7

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon