Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SPRING-8 BEAMLINE BL41XU |
| Synchrotron site | SPring-8 |
| Beamline | BL41XU |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2015-07-22 |
| Detector | RAYONIX MX225HE |
| Wavelength(s) | 0.9 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 115.621, 117.810, 493.203 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 15.990 - 2.900 |
| R-factor | 0.274 |
| Rwork | 0.270 |
| R-free | 0.30740 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 6KPU |
| RMSD bond length | 0.005 |
| RMSD bond angle | 0.926 |
| Data reduction software | HKL-2000 |
| Data scaling software | SCALEPACK |
| Phasing software | MOLREP |
| Refinement software | PHENIX (1.19.2) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 3.030 |
| High resolution limit [Å] | 2.900 | 2.900 |
| Rmerge | 0.080 | 0.374 |
| Number of reflections | 73353 | 297 |
| <I/σ(I)> | 6.5 | |
| Completeness [%] | 48.8 | 1.5 |
| Redundancy | 8.1 | 1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.1 | 288 | 175mM MgCl2, 18% (w/v) PEG 2000 MME, 10% (w/v) glycerol, 5mM GSH, 0.1mM DTT, 1mg/ml butylhydroxytoluen, 100mM MES |