Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7WPH

SARS-CoV2 RBD bound to Fab06

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]80
Detector technologyPIXEL
Collection date2021-06-30
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.9464
Spacegroup nameP 21 21 2
Unit cell lengths50.170, 266.350, 112.610
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution48.150 - 2.890
R-factor0.2306
Rwork0.229
R-free0.26940
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)7c01
RMSD bond length0.012
RMSD bond angle1.553
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.18.2_3874)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]55.0002.993
High resolution limit [Å]2.8902.890
Rmeas0.332
Rpim0.101
Number of reflections349043389
<I/σ(I)>8.311.22
Completeness [%]99.896.7
Redundancy10.4
CC(1/2)0.9940.522
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293.150.2M magnesium formate dihydrate, 20% w/v PEG 3350

219869

PDB entries from 2024-05-15