7UQL
Pathogenesis related 10-10 app from
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRL BEAMLINE BL12-2 |
| Synchrotron site | SSRL |
| Beamline | BL12-2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2020-10-03 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.9795 |
| Spacegroup name | P 21 21 2 |
| Unit cell lengths | 70.175, 92.547, 52.858 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 35.090 - 1.900 |
| R-factor | 0.2104 |
| Rwork | 0.207 |
| R-free | 0.24740 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 6ka3 |
| RMSD bond length | 0.010 |
| RMSD bond angle | 0.947 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.18.2-3874) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 38.600 | 1.950 |
| High resolution limit [Å] | 1.900 | 1.900 |
| Number of reflections | 27479 | 1977 |
| <I/σ(I)> | 27.42 | |
| Completeness [%] | 98.5 | |
| Redundancy | 8.1 | |
| CC(1/2) | 1.000 | 0.849 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | PEG 3350, Bis-Tris pH 5.5 |