7UC7

Stat5a Core in complex with Compound 17

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-F
Synchrotron siteAPS
Beamline21-ID-F
Temperature [K]100
Detector technologyCCD
Collection date2021-03-24
DetectorRAYONIX MX-300
Wavelength(s)0.9787
Spacegroup nameH 3 2
Unit cell lengths238.895, 238.895, 113.304
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution45.880 - 3.102
R-factor0.2248
Rwork0.222
R-free0.28140
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)previously solved structure in lab
RMSD bond length0.009
RMSD bond angle1.030
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwareBUSTER (2.10.4 (3-FEB-2022))
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0003.150
High resolution limit [Å]3.1008.4003.100
Rmerge0.0760.0351.515
Rmeas0.0790.0371.586
Rpim0.0240.0120.466
Total number of observations256562
Number of reflections2246011681101
<I/σ(I)>7
Completeness [%]99.998.8100
Redundancy11.410.311.6
CC(1/2)0.9970.914
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2931.1M Ammonium Tartrate dibasic pH 7.0

219869