Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7U57

apo-CTX-M-15

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 5.0.1
Synchrotron siteALS
Beamline5.0.1
Temperature [K]80
Detector technologyPIXEL
Collection date2020-12-18
DetectorDECTRIS PILATUS3 6M
Wavelength(s)1
Spacegroup nameC 1 2 1
Unit cell lengths171.079, 51.033, 106.863
Unit cell angles90.00, 112.59, 90.00
Refinement procedure
Resolution51.710 - 2.370
R-factor0.226
Rwork0.222
R-free0.32680
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4hbt
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX (1.19.1_4122)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]51.7109.0001.760
High resolution limit [Å]1.7304.6901.730
Rmerge1.226
Number of reflections74931711
<I/σ(I)>2
Completeness [%]75.0
Redundancy1.21.21
CC(1/2)0.9350.3130.935
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.8293300 mM Ammonium sulfate, 30% PEG 4000

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon