7U57
apo-CTX-M-15
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 5.0.1 |
Synchrotron site | ALS |
Beamline | 5.0.1 |
Temperature [K] | 80 |
Detector technology | PIXEL |
Collection date | 2020-12-18 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 1 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 171.079, 51.033, 106.863 |
Unit cell angles | 90.00, 112.59, 90.00 |
Refinement procedure
Resolution | 51.710 - 2.370 |
R-factor | 0.226 |
Rwork | 0.222 |
R-free | 0.32680 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4hbt |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.19.1_4122) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 51.710 | 9.000 | 1.760 |
High resolution limit [Å] | 1.730 | 4.690 | 1.730 |
Rmerge | 1.226 | ||
Number of reflections | 74931 | 71 | 1 |
<I/σ(I)> | 2 | ||
Completeness [%] | 75.0 | ||
Redundancy | 1.2 | 1.2 | 1 |
CC(1/2) | 0.935 | 0.313 | 0.935 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.8 | 293 | 300 mM Ammonium sulfate, 30% PEG 4000 |