7T0L
HLA-B*27:05 in complex with the pan-HLA-Ia monoclonal antibody W6/32
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2017-06-12 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.954 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 142.785, 146.660, 177.875 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 42.580 - 3.000 |
R-factor | 0.2006 |
Rwork | 0.198 |
R-free | 0.25170 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2A83 and 2Q8A |
RMSD bond length | 0.008 |
RMSD bond angle | 1.010 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | BUSTER (2.10.2) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 3.200 |
High resolution limit [Å] | 3.000 | 3.000 |
Rmerge | 0.130 | 0.710 |
Number of reflections | 37696 | 5427 |
<I/σ(I)> | 5.7 | |
Completeness [%] | 100.0 | 100 |
Redundancy | 6.9 | 7.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6 | 298 | PEG 5000 MME, 0.1 M Bis-Tris pH 6.0 |